Download Print this page

Feig Electronic OBID i-scan ID ISC PRHD102 Manual page 72

Standard-reader

Advertisement

®
OBID i-scan
6.8. [0x72] Set Output
The command Set Output serves temporary limited or unlimited activation of the outputs of the
Reader.
Each output takes on the state defined by the byte OUTx-mode for the period of time (OUT-TIME)
included in the protocol. The flashing frequency is defined by the byte OUTx-frq. Via this protocol
the outputs can be switched on or off for the indicated period of time. If the Reader receives a
command Set Output, all times that have been active until then are being overwritten by the new
times included in the protocol if they are > 0.
Host → Reader
1
0x02
Host ← Reader
1
0x02
Mode:
0x01 (reserved)
OUT-N:
Defines the number of output records.
OUT-NR:
Defines the Type and the number of the output
Bit:
Function:
OUT-type:
b0
The following outputs are available:
– OUT-1: LED green
– OUT-2: LED blue
– OUT-3: LED red
– OUT-4: Beeper
14
see ANNEX D: Index of Status Bytes
FEIG ELECTRONIC GmbH
2
3
n
8
OUT-NR
Repeated OUT-N times
2
3
n
7
6
5
OUT-
type
Digital Output
Manual
4
COM-ADR
[0x72]
9
10,11
OUT-S
OUT-TIME
4
COM-ADR
[0x71]
4
3
2
OUT-Number
Page 72 of 125
ID ISC.PRHD102
5
6
Mode
n-1...n
CRC16
5
6
14
STATUS
1
0
H71101-2e-ID-B.doc
7
OUT-N
7,8
CRC16

Advertisement

loading