2
Setting up the M5302A module

2.2.6: Installing the Module

40
Plan your module position. Before installing the module, remove plastic
thread protectors on the top and bottom of mounting screws. Install the
left-most module first and continue installing modules from left to right
according to
When installing the M5302A module:
1
Hold the module by the injector/ejector handle and make sure that the
injector/ejector handle is pushed down in the unlatched (downward)
position. Slide the module into chassis, using the slot guides (top and
bottom).
2
Slide the module into position. When you begin to feel resistance, pull
up the injector/ejector handle to fully inject the module into the
chassis backplane connectors.
3
Tighten the module retaining screws (top and bottom) and torque them
to 5 Lb-In (0.57 N-m).
Figure 12
The image above shows generic module installation. It may not reflect
NOTE
your module's actual size and chassis placement.  
Figure
12.
Depiction of installing a PXIe module