Main Parts
A)Cooking well: in stainless steel.
B)Fume exhaust vent (Type (A): for removal of the
fumes generated by the burner
C)Fume exhaust vent (type B11): removes the fumes
and conveys them to a flue fitted with an extraction
system serving the gas system.
D)Fume exhaust vent (type B11): removes the fumes
and conveys them to a flue with natural draft and with
draught damper device.
E)Burner control knob: controls the supply of gas to
the burner
F) Water control knob: for regulating the water flow.
G)Ignition button: switches the burner on
H)Mains light: indicates that the appliance is receiving
electrical power.
L) Adjustable water spout: directs the flow of water
M)Hatches: for accessing the inside of the appliance.
N)Gas supply connection: for connection of the
gas supply.
See tables and "Connection chart" at the back
of the manual.
IT
IT
AUS
GB
Although the appliance is complete with all safety
DE
DE
devices, during installation and connection addi-
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
FR
FR
The illustration shows the position of the devices.
A)Gas supply tap: for turning the connection to the
ES
ES
gas supply line on and off.
B)Safety thermocouple: cuts out the gas supply if the
flame goes out.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
English
TECHNICAL DATA
SAFETY DEVICES
D
A
L
H
E
F
F
E
M
G
- 4 -
C
B
N
L A
IDM-39614900300.tif
B
A
IDM-39614900400.tif
B
H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

191cp2g

Table of Contents