Caution - warning
This appliance shall be installed only by author-
ised persons and in accordance with the manu-
facturer's installation instructions, local gas
fitting regulations, municipal building codes,
electrical wiring regulations, local water supply
regulations, AS 5601-2004 - Gas Installations
and any other statutory regulations.
All installation stages must be considered right from
production of the general layout. Before starting these
stages, as well as deciding the place of installation, if
necessary, the person authorised to carry out these
operations must organise a "safety plan" to protect the
people directly involved, and he must also ensure
strict compliance with all legal requirements, especial-
ly those relating to mobile work-sites.
The place of installation must have all the connections
needed to supply the appliance and dispose of
the production residues, must be suitably lit and
must meet all legal health and hygiene require-
The room where the appliance is installed must
have air inlets to ensure that the appliance can op-
erate correctly and provide the necessary air ex-
change in the room itself.
IT
The air inlets must be of appropriate size and must
be protected by gratings and placed so that they
cannot be obstructed.
AUS
Caution - warning
DE
Ventilation must be in accordance with
AS5601-2004 - Gas Installations. In general,
FR
the appliance should have adequate ventila-
tion for complete combustion of gas, proper
flueing and to maintain temperature of imme-
ES
diate surroundings within safe limits.
Screw the feet (A) onto the structure in the connec-
tion points.
English
INSTALLATION OF THE APPLIANCE
ROOM VENTILATION
INSTALLING ACCESSORIES
ments to prevent the contamination of the foods.
If necessary, fix the exact position of each individual
appliance or subassembly by mark coordinates to
locate them correctly.
Always leave a minimum clearance of 5cm from the
rear of the appliance to the wall except if the wall,
the internal structure and its coating is non-combus-
tible. If any internal part of the wall is made from a
combustible material, leave a 5cm gap regardless
of the external cladding on the wall. .
- 14 -
IDM-39614901200.tif
IDM-39614901300.tif
A
IDM-39614401500.tif