091CP1G
GAS TPP (1) Supply pressure
NGN
0.9 kPa
1.13 kPa
ULPG 2.65 kPa
2.75 kPa
(1) -Test point pressure on manifold
(2) - Nominal gas consumption
(2.1) - Main burner injector size
(3) - Turndown gas consumption
191CP2G
GAS TPP (1) Supply pressure
NGN
0.9 kPa
1.13 kPa
ULPG 2.65 kPa
2.75 kPa
(1) -Test point pressure on manifold
(2) - Nominal gas consumption
(2.1) - Main burner injector size
(3) - Turndown gas consumption
N.G.C. (2)
G.C.
Ø (2.1)
56 MJ/h
3.60 mm
26 MJ/h 1.45 mm
56 MJ/h
2.05 mm
22 MJ/h 1.45 mm
N.G.C. (2)
G.C.
Ø (2.1)
112 MJ/h 3.60 mm
26 MJ/h 1.45 mm
112 MJ/h 2.05 mm
22 MJ/h 1.45 mm
-
V
T.G.C. (3)
G.C.
Ø (3.1)
p (3.2)
adj-pressure
0.15 kPa
fully
tightened
0.40 kPa
(3.1) - Bypass injector size
(3.2)- Bypass test point pressure on outlet of gas valve
(4) - Pilot injector size
(5) - Iron Ring holes
T.G.C. (3)
G.C.
Ø (3.1)
p (3.2)
adj-pressure
0.15 kPa
fully
tightened
0.40 kPa
(3.1) - Bypass injector size
(3.2)- Bypass test point pressure on outlet of gas valve
(4) - Pilot injector size
(5) - Iron Ring holes
-
Pilot
Iron Ring
flame
Ø (4)
Ø (5)
0.40
6 holes x5.5 mm
mm
adjusted to 26 mm
0.25
6 holes x5.5 mm
mm
adjusted to 21 mm
Pilot
Iron Ring
flame
Ø (4)
Ø (5)
0.40
6 holes x5.5 mm
mm
adjusted to 26 mm
0.25
6 holes x5.5 mm
mm
adjusted to 21 mm