Atto Fibrebridge 1190E Characteristics - ATTO Technology FibreBridge 1190E Installation And Operation Manual

Atto technology fibrebridge 1190e bridges: user guide
Table of Contents

Advertisement

3 ATTO FibreBridge 1190E characteristics

The ATTO FibreBridge
to SCSI bridge for high throughput enterprise environments designed for mission-critical applications.
The FibreBridge 1190E features a small form
factor for standard embedded applications such as
tape drives, hard disk drives and other SCSI
devices and includes serverless backup support
and support for manual and auto LUN mapping
Dimensions
➔ 4.2 inches wide
➔ 7.6 inches long
Cooling
Environmental requirements
o
➔ 0-40
C
➔ Ambient air should not exceed 70
➔ 10-90% humidity non-condensing
Power
Power (+5 V and +12V) is supplied to the
FibreBridge 1190E through a standard PCI
connector or a 4-pin connector, the default: Amp
Part no: 641737-1. The 1190E is designed to have
±5% tolerance to the power supply. A switching
regulator generates 3.3V from either 5V or 2V,
requiring 0.75A at12V. Jumper-enabled power
from a PCI connector is also possible.
Fibre Channel port
The Fibre Channel port can connect the
FibreBridge to either a Fabric or Arbitrated Loop.
➔ 1.0625 gigahertz (100 MB/sec.)
➔ Class 2, Class 3 and Intermix ANSI Fibre
Channel specifications support
➔ PLDA, Public Loop Login (NL_port) and
Fabric Direct Connect (N_port) support
➔ Full Duplex transmission support
➔ MIA compliant DB-9 or Short Wave fiber
optic SE connector
5 ATTO Technology FibreBridge 1190E Installation and Operation Manual
TM
1190E is a 1 x 2 (one Fibre Channel port with two SCSI ports) Fibre Channel
o
C.
SCSI ports
The two SCSI ports on the FibreBridge 1190E
connect storage devices into the Fibre Channel
Storage Area Network (SAN). Each port is totally
independent from the others.
The FibreBridge 1190E SCSI port is an Ultra 2
(LVD) SCSI with 80 MB/sec. maximum per bus,
downward compatible with all forms of single-
ended SCSI.
Exhibit 3-1 Graphical representation of the
FibreBridge 1190E with ShortWave fiber optic SE
connector (top) or MIA compliant DB-9 connector
(bottom).

Advertisement