ATTO Technology FibreBridge 1190E Installation And Operation Manual page 15

Atto technology fibrebridge 1190e bridges: user guide
Table of Contents

Advertisement

FibreBridge. The FibreBridge SCSI ports must be
set to different SCSI IDs than the devices on the
bus.
SCSI devices are mapped manually to desired
Fibre Channel port and Fibre Channel LUNs.
Manual mapping allows you to maximize the
efficiency and performance of your SCSI devices
while allowing great flexibility.
Manual SCSI Device Mapping
The FibreBridge can be commanded to find all the
SCSI devices on its SCSI bus. With this
information you then decide where you want to
place these devices on the Fibre Channel ports.
In the chart at right, the SCSI device on SCSI bus
0 at SCSI address of ID 0 LUN 0 is being mapped
to Fibre Port 0 (on the FibreBridge) at Fibre
Channel LUN 4.
Note: two SCSI devices cannot be mapped to
the same Fibre Port and Fibre Channel LUN.
Also, if the same SCSI device is mapped to two
different Fibre Port and/or Fibre Channel
LUN, these Fibre Port and Fibre Channel
LUNs will be taken offline automatically until
the conflict is resolved.
You may map SCSI devices manually by using the
Command Line Interface RouteXXX family of
commands. See Chapter 7.1.2 for more details.
Fibre
FC LUN
SCSI
Port
BUS
0
4
0
0
0
0
0
2
0
0
0
0
0
3
0
0
10
0
0
30
0
0
23
0
SCSI ID
SCSI
LUN
0
0
1
0
13
0
15
0
1
0
1
1
8
5
8
7
10

Advertisement

Table of Contents
loading

Table of Contents