7.1.6 Serial Port configuration commands
The ATTO FibreBridge
specifications using the CLI commands in this section.
CLI commands are case insensitive (lower case
allowed anywhere).
SerialPortBaudRate
Configures/reports the baud rate for the FibreBridge RS-232 serial port. The number of data bits per character is fixed at 8 with no parity.
Limits: 2400, 9600, 19200, 38400, 57600, 115200
Actions: set SerialPortBaudRate [2400 | 9600 |19200 |
38400 | 57600 |115200]
SaveConfiguration
SerialPortEcho
Enables/disables/reports the echoing of keyboard input. When enabled, all non-control character keyboard input is output to the display.
Limits: Local ASCII terminal (or terminal emulator) echo
settings should be set to disabled while using
SerialPortEcho enabled
Actions: setSerialPortEcho [enabled | disabled]
SaveConfiguration Restart
SerialPortHandshake
Configures/reports the data handshaking method used to control the flow between the transmitter and receiver using hardware flow control, software
flow control (Xon/Xoff)or no flow control.
Limits: hard (hardware flow control), xon (software flow
control) or no flow control (none)
Actions: set SerialPortHandshake [hard | xon | none]
SaveConfiguration
SerialPortStopBits
Configures/reports the number of stop bits per character for the FibreBridge RS -232 serial port. The number of data bits per character is fixed at
8 with no parity.
Limits: 1 or 2
Actions: set SerialPortStopBits [1 | 2]
SaveConfiguration
25 ATTO Technology FibreBridge Installation and Operation Manual
TM
serial ports are configured with default settings but may be customized to your
Commands generally follow a standard format:
[Get | Set] Command [Parameter 1 | Parameter 2]
followed by the return or enter key
Default: 11520
Information: get SerialPortBaudRate
Default: enabled
Information: get SerialPortEcho
Default: no flow control (none)
Information: getSerialPortHandshake
Default: 1 stop bit
Information: get SerialPortStopBits