0 will repeat the cycle indefinitely, and values in the range of 1 cycle to 255 cycles will execute
that number of cycles.

3.5.2.2 On Time

This parameter allows you to configure the time that a breaker will be ON during a cycle. This
can be set to a value in the range of 0 seconds to 6553.5 seconds in increments of 0.1
seconds.

3.5.2.3 Off Time

This parameter allows you to configure the time that a breaker will be OFF during a cycle. This
can be set to a value in the range of 0 seconds to 6553.5 seconds in increments of 0.1
seconds. A value of 0 will disable this flash map.

3.5.3 Discrete I/O

When a device transmitting the 127501 Binary Status Report message is part of the
installation, it can be configured to control the behavior of the breakers. This includes the
seven input channels present on the CLMD12. Up to thirty-six Discrete I/O's can be
programmed. One Discrete I/O can control multiple breakers up to the box limit. The Discrete
I/O state is maintained independent of any breaker state. Therefore, if a breaker is being
controlled from multiple input signals (DIO's), an "out of state" situation is possible when input
signals are switched. Example: two wall switches are controlling the same light (breaker),
depending on the state of the signal a second touch of the switch may be required to obtain
the desired action.