3.4.2 Breaker Connections

The CLMD12 breaker connections are made by connecting to the 12-pin J1 connector. The pin
number on the J1 connector corresponds to a breaker number, which is represented as an
indicator number in the 127501 Binary Status Report message or as a Connection ID in the
127500 Load Controller Connection & State message. The correspondence of the J1 connector
pin number to the channel number is detailed in the table below, along with the maximum current
supported by the channel.
J1
Description
Connector
Pin No.
1
Breaker #5
2
Breaker #4
3
Breaker #8
4
Breaker #2
5
Breaker #10
6
Breaker #1
7
Breaker #11
8
Breaker #3
9
Breaker #12
10
Breaker #6
11
Breaker #9
12
Breaker #7

3.4.3 Discrete Input Connections

Connect each discrete input channel to a pin on the J2 connector as shown in the table below.
Each connection may switch between open circuit and system ground or the supply voltage.
J2
Connector
Pin No.
1
Discrete Input #3 (active high/open/active low)
2
Discrete Input #1 (active high/open/active low)
3
Discrete Input #7 (active high/open/active low)
4
Discrete Input #5 (active high/open/active low)
5
Discrete Input #6 (active high/open/active low)
6
System Ground
7
Discrete Input #2 (active high/open/active low)
8
Discrete Input #4 (active high/open/active low)
Page 10
NMEA 2000 PGN
127501 Indicator
Number
5
4
8
2
10
1
11
3
12
6
9
7
Description
NMEA 2000 PGN
127500 Connection
ID
4
3
7
1
9
0
10
2
11
5
8
6
NMEA 2000 PGN 127501
Indicator Number
Max Output
AMPS
10
12
10
10
10
10
10
5
5
5
5
12
15
13
19
17
18
N/A
14
16