Parameter
Simulated Solar Radiation
Altitude (Transport)
Altitude (Operational)
Humidity (Soak)
Humidity - Cyclic
Dust Ingress
Water Ingress
Mechanical Shock - Drop Test
Mechanical - Shock
Mechanical - Bump
Vibration (General)
Vibration (Random)
Vibration (Resonant Search)
Chemical Resistance
Salt Spray
Ozone
Electrical (Operating Voltage)
Electrical (Over Voltage)
Electrical (Reverse Polarity)
Electrical (Short Circuit)
Electrical (Power Up)
Component Test - Electrical
Transients Immunity
Component Test - Electrical
Transients Emissions
Component Test - Electrical
Transients Conducted Transients
Electrostatic Discharge (ESD)
Ignition Protection Test

8 Mechanical Drawing

Revision 1.6
Standard
EN 60068-2-5:2010
EN 60068-2-13:1999
EN 60068-2-13:1999
EN 60068-2-78:2002
EN 60068-2-30:2005
IEC 60529:2001
DIN 40050-9:1993
IEC 60529:2001
EN 60068-2-32:1993
60068-2-27:2009
60068-2-29:1993
60068-2-6: 1996
EN 60068-2-64:1995
60068-2-6: 1996
EN 60068-2-74:2000
EN 60068-2-52: 1996
ASTM D1171-99
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
SAE J1455:2011 Sect 4.13.1
ISO 11451-1:2005
ISO 11452-2:2004
ISO 13766:2006 Section 5
Annex D and Annex E
ISO 13766:2006
ISO 7637-2:2011
ISO 13766:2006
SO 8846:201, SAE J1171:2016
Conditions
Procedure = B, 10 days @ 40°C
ALT
= Sea Level, ALT
min
ALT
= Sea Level, ALT
min
RH = 93% +/-3%, Exposure 10 days
RH (> 90%), 6 cycles of 24hrs
Method EN60529 Section 13 Result
IP6X
Method as DIN 40050-9 Result IP67
1000mm free-fall, all faces of 3 axes
2
500m/s
, pulse duration 11ms
2
400m/s
6ms shock pulses, 3 axes
Sine shaped sweep 5 Hz to 500 Hz
Method 1
frequency range 10 Hz – 2 kHz @ 5G
Test method = B
Chamber Temperature = 35°C
Method A rating 0
Test for impaired function
Test for impaired function +24V, +36V
Test for impaired function -24V, -36V
Operate at: +16V, +32V
Ramp: 0 to 9 VDC, 0 to 18 VDC
Refer to STD00140_2 - Table 17.
100 V/m
Distance of 1 m in the horizontal and
vertical polarization, 30 MHz to 1 GHz
Method as per ISO 7637-2-Annex A
+/- 8 kV (Direct), +/- 15 kV (Air)
USCG recommended procedures
= 13600m
max
= 4850m
max