Maretron MPOWER CLMD12 User Manual page 23

12channel dc load controller module
Hide thumbs Also See for MPOWER CLMD12:
Table of Contents

Advertisement

3.5.1.6.16
Voltage
This read-only field shows the real-time voltage at the load terminal of the breaker.
3.5.1.6.17
Flash Map
This parameter allows you to configure a breaker to use a flash map. A value of 0 means that
the breaker is not assigned to any flash map, and a value of 1 through 15 assigns the breaker
to the flash map corresponding to that number.
3.5.1.6.18
User Config Allowed
This parameter allows you to configure whether configuration changes can be made to the
breaker. If this is checked, other configuration parameters for the breaker can be changed. If
this is cleared, other configuration parameters for the breaker cannot be changed.
3.5.1.6.19
Status
This group of indicators show real-time status of the breaker.
3.5.1.6.19.1
Short Load
When lit, this read-only field indicates that the breaker has tripped due to a detected short
circuit.
3.5.1.6.19.2
Breaker Locked
When lit, this read-only field indicates that the breaker has been locked and will not respond to
switch commands on the network. The purpose of the lock feature is to avoid inadvertent or
accidental breaker state changes. The breaker must be unlocked before the breaker state can
be remotely changed again.
3.5.1.6.19.3
Breaker Tripped
When lit, this read-only field indicates that the breaker has tripped due to an overcurrent
condition. Switch the breaker OFF to acknowledge the 'breaker tripped' indication. You can
then switch the breaker back to the ON position.
3.5.1.6.19.4
Breaker ON
When lit, this read-only field indicates that the breaker is in the ON state.
3.5.1.6.19.5
Open Load
When lit, this read-only field indicates an Open Load (no load) condition which indicates that
the breaker is turned ON but there is little or no current being drawn. Possible conditions:
• External switch controlling load is in the OFF position
• If the connected load is a light, the bulb could be defective
• The load is miswired
• The load is very small (less than 1.0 Amp)
3.5.1.6.19.6
Communications Error
When lit, this read-only field indicates that the breaker has lost communication with the main
processor.
3.5.1.6.19.7
Breaker Communicating
When lit, this read-only field indicates that the breaker is communicating with the network.
Revision 1.6