Input Voltage; Not Configured; Serial Number Invalid; Breaker #N - Maretron MPOWER CLMD12 User Manual

12channel dc load controller module
Hide thumbs Also See for MPOWER CLMD12:
Table of Contents

Advertisement

3.5.1.3 Input Voltage

This field allows you to configure nominal expected input voltage of the CLMD12. Choose from
one of the following selections:
• 12 VDC
• 24 VDC
• 36 VDC
• Undefined

3.5.1.4 Not Configured

When lit, this read-only field indicates that the CLMD12 does not contain a valid configuration.

3.5.1.5 Serial Number Invalid

When lit, this read-only field indicates that the CLMD12 does not contain a valid serial number.
Please contact Maretron technical support for assistance.

3.5.1.6 Breaker #n

This section contains settings for the specified circuit breaker. One of these sections is present
for each of the breakers in the unit.
3.5.1.6.1 Label
This text box allows you to configure a text label for the breaker to identify it (for example,
"RUNNING LIGHTS" or "HATCH"). For each breaker, set this to a value which describes the
breaker so that you can easily identify it in display devices.
3.5.1.6.2 State
This read-only field indicates the current state of the breaker. It will contain one of the following
values:
• OFF
• ON
3.5.1.6.3 Default State
This allows you to configure the state of the breaker when the CLMD12 is powered on. You
can set this to one of the following values:
• OFF
• ON
• LAST KNOWN STATE
3.5.1.6.4 Default Lock State
This parameter allows you to configure whether the breaker is locked when the CLMD12 is
powered on. You can set this to one of the following values:
• LOCKED
• UNLOCKED
3.5.1.6.5 Sound Alarm When Tripped
This parameter allows you to configure whether an alarm is sounded on OctoPlex Touch
Screen displays whenever the breaker is tripped.