15. You may use a level (optional) to verify correct inclination of 1.5° towards the tank
16. Tighten the finger nut firmly.
17. Tighten the upper nut to lock the finger nut (you may temporarily remove the
18. Wire the gauge and configure by using the RosemountTankMaster WinSetup
Rosemount 5900C Radar Level Gauge
center. Ensure that the level is put on a flat and steady surface on top of the
transmitter head. If needed, loosen the finger nut and adjust the gauge.
Note
Make sure the air bubble touches, but doesn't overlap the 1.5° mark.
A. Finger Nut
transmitter head to make room for tools if needed), and secure by folding the tab
washer over the nut.
A
A. Upper Nut
software (see the Rosemount Tank Gauging
September 2019
System Configuration
Manual).
Installation
59