Specifications and reference data
September 2019
A.13.3
Rosemount 5900C Radar Level Gauge with still-pipe
array antenna
Table A-9: Rosemount 5900C Radar Level Gauge with Still-Pipe Array Antenna Ordering Information
Model
Product Description
5900C
Radar Level Gauge
Performance class
2
±2 mm (0.08 in.) instrument accuracy
Safety certification (SIS)
(1)
S
Certified IEC 61508 SIL 2 capable
F
None. Ready for upgrade to Safety certification (SIS)
0
None
Redundancy
1
None. Single radar level gauge electronics
Tankbus: Power and communication
F
Bus powered 2-wire F
Hazardous location certification
I1
ATEX Intrinsic Safety
I7
IECEx Intrinsic Safety
I5
FM-US Intrinsic Safety
I6
FM-Canada Intrinsic Safety
I2
INMETRO Intrinsic Safety (Brazil)
IP
KC Intrinsic Safety (South Korea)
IW
CCOE/PESO Intrinsic Safety (India)
(2)
I4
Japan Intrinsic Safety
IM
Technical Regulations Customs Union (EAC) Intrinsic Safety
NA
None
Custody transfer type approval
0
None
Level measurement method
1
10 GHz FMCW radar technology
2
10 GHz FMCW radar technology for US installation
Housing
A
Standard enclosure, polyurethane-covered aluminum. IP 66/67
Cable entry/Conduit connections
1
½ - 14 NPT, female thread. (1 plug included)