Emerson Rosemount 5900C Reference Manual page 288

Radar level gauge
Table of Contents

Advertisement

Product Certifications
September 2019
Special Conditions for Safe Use (X):
1. The Model 2051 transmitter housing contains aluminum and is considered a
IF Canada Intrinsic Safety
Certificate
Standards
Markings
B.16.2
Europe
IA ATEX FISCO
Certificate
Standards
Markings
FISCO
parameters
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90V transient suppressor, it is incapable
2. The enclosure may be made of aluminum alloy and given a protective polyurethane
B.16.3
International
IG IECEx FISCO
Certificate
Standards
Markings
288
potential risk of ignition by impact or friction. Care must be taken into account
during installation and use to prevent impact and friction.
2041384
CSA Std. C22.2 No. 142 - M1987, CSA Std. C22.2 No. 213 - M1987, CSA
Std. C22.2 No. 157 - 92, ANSI/ISA 12.27.01 – 2003, CAN/CSA-
E60079-0:07, CAN/CSA-E60079-11:02
Intrinsically safe for Class I, Division 1, Groups A, B, C, and D when
connected in accordance with Rosemount drawing 02051-1008. Ex ia
IIC T3C. Single Seal. Enclosure Type 4X
Baseefa08ATEX0129X
EN60079-0:2012+A11:2013, EN60079-11:2012
II 1 G Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Ui
Ii
17.5V
380 mA
of withstanding the 500V isolation from earth test and this must be taken into
account during installation.
paint finish; however care should be taken to protect it from impact and abrasion
when located in Zone 0.
IECExBAS08.0045X
IEC60079-0:2011, IEC60079-11:2011
Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Pi
Ci
5.32 W
0 µF
Reference Manual
00809-0100-5901
Li
0 mH
Reference Manual

Advertisement