Emerson Rosemount 5900C Reference Manual page 318

Radar level gauge
Table of Contents

Advertisement

F
Fieldbus Block Information
OUNDATION
September 2019
Table C-23: LPG-Hybrid Transducer Block Parameters
Index
Number
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
318
Parameter
BLOCK_ALM
TRANSDUCER_DIRECTORY
TRANSDUCER_TYPE
TRANSDUCER_TYPE_VER
XD_ERROR
COLLECTION_DIRECTORY
LPG_SPECIAL_CONTROL
LPG_CORRECTION_METHOD
LPG_NUMBER_OF_GASSES
LPG_GAS_TYPE1
LPG_GAS_PERC1
LPG_GAS_TYPE2
LPG_GAS_PERC2
LPG_GAS_TYPE3
LPG_GAS_PERC3
LPG_GAS_TYPE4
LPG_NUMBER_OF_PINS
LPG_PIN1_CONFIGURATION
LPG_PIN2_CONFIGURATION
LPG_PIN3_CONFIGURATION
LPG_PIN_TEMPERATURE
LPG_PIN_TEMP_EXP_PPM
LPG_CORRECTION_ERROR
LPG_CORRECTION_STATUS
LPG_USED_GAS_PRESSURE
(continued)
Description
The block alarm is used for all configuration,
hardware, connection failure or system problems
in the block. The cause of the alert is entered in
the subcode field. The first alert to become active
will set the Active status in the Status parameter.
As soon as the Unreported status is cleared by the
alert reporting task, another block alert may be
reported without clearing the Active status, if the
subcode has changed.
Directory that specifies the number and starting
indices of the transducers in the transducer block.
Identifies the transducer.
A transducer block alarm sub code.
A directory that specifies the number, starting
indices, and DD Item ID's of the data collections in
each transducer within a transducer block.
Special Control
Correction method
Number of gases
Gas type 1
Percentage of gas type 1 in mixture of gases
Gas type 2
Percentage of gas type 2 in mixture of gases
Gas type 3
Percentage of gas type 3 in mixture of gases
Gas type 4
Number of verification pins in the Still-pipe
Nominal position of Verification pin 1
Nominal position of Verification pin 2
Nominal position of Verification pin 3
Ambient temperature when Verification Pin
nominal position was entered.
Expansion coefficient of still-pipe with verification
pin
Correction error
Correction status
Gas pressure