Load Management
Load management can be used after your system is setup and your loads (lights) are
connected to dimmers. For load management to work properly, Load Errors must be
enabled for each dimmer you want to monitor. Load Errors is not enabled on any dimmers
by default.
R e c o r d L o a d s
When you record loads, the CEM+ steps through a series of dimmer intensities and
monitors the wattage as it proceeds. Only dimmers that have an initial intensity level
greater than zero (0) are included in the process.
Once loads have been recorded, load changes and missing loads are reported at the face
panel LCD menu and in the web interface.
C l e a r L o a d s ( W e b O n l y )
Clearing loads will clear all previously recorded loads. Clearing loads is only available via
the web interface.
Clear Errors
Errors will appear on both the face panel LCD and in the web interface.
When viewing errors on the face panel LCD at an access level of User or higher, pressing
will clear that error. Continuing to press
clear any that are capable of being cleared. Errors that are still current will quickly reappear
in the list (such as No Data Port B or Module Removed).
From the web interface, you can view the errors present from a couple of locations,
however you can only clear errors from the individual rack's errors tab webpage. From this
page you will have the option to checkmark and clear individual errors or to clear all errors.
4
CEM+ Configuration Procedures
will cycle through the remaining errors and
42