AMX Modero NXD-700Vi Operation/Reference Manual page 181

G4 touch panels 7” modero widescreen video touch panels with full duplex intercom
Hide thumbs Also See for Modero NXD-700Vi:
Table of Contents

Advertisement

These fields are populated differently for each query command. The text length (String Encode) field is
not used in any command.
Button Query Commands
?BCB
Syntax:
Get the current
"'?BCB-<vt addr range>,<button states range>'"
border color.
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
custom event type 1011:
Flag - zero
Value1 - Button state number
Value2 - Actual length of string (should be 9)
Value3 - Zero
Text - Hex encoded color value (ex: #000000FF)
Text length - Color name length (should be 9)
Example:
SEND COMMAND Panel,"'?BCB-529,1'"
Gets the button 'OFF state' border color. information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1011
Flag = 0
VALUE1 = 1
VALUE2 = 9
VALUE3 = 0
TEXT = #222222FF
TEXT LENGTH = 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents