AMX Modero NXD-700Vi Operation/Reference Manual page 171

G4 touch panels 7” modero widescreen video touch panels with full duplex intercom
Hide thumbs Also See for Modero NXD-700Vi:
Table of Contents

Advertisement

Set the button size and its position on the page.
^BSP
Set the button
Syntax:
size and position.
"'^BSP-<vt addr range>,<left>,<top>,<right>,<bottom>'"
Variable:
variable text address range = 1 - 4000.
left = left side of page.
top = top of page.
right = right side of page.
bottom = bottom of page.
Example:
SEND_COMMAND Panel,"'^BSP-530,left,top'"
Sets the button with variable text 530 in the left side top of page.
^BVL
Syntax:
Log-On/Log-Off
"'^BVL-<vt addr range>,<connection>'"
the computer
Variable:
control
variable text address range = 1 - 4000.
connection.
connection = 0 (Log-Off connection) and 1 (Log-On connection).
Example:
SEND_COMMAND Panel,"'^BVL-500,0'"
Logs-off the computer control connection of the button.
Syntax:
^BVN
Set the network
"'^BVN-<vt addr range>,<network name>'"
name for the
Variable:
specified address.
variable text address range = 1 - 4000.
network name = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"
Sets the network name to '191.191.191.191' for the specific control button.
^BVP
Syntax:
Set the network
"'^BVP-<vt addr range>,<network password>'"
password for the
Variable:
specified address.
variable text address range = 1 - 4000.
network password = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"
Sets the password to PCLOCK for the specific PC control button.
^BVT
Syntax:
Set the computer
"'^BVT-<vt addr range>,<network port>'"
control network
Variable:
port for the
variable text address range = 1 - 4000.
specified address.
network port = 1 - 65535.
Example:
SEND_COMMAND Panel,"'^BVT-500,5000'"
Sets the network port to 5000.