Determines what order each layer of the button is drawn.
^BDO
Set the button
Syntax:
draw order.
"'^BDO-<vt addr range>,<button states range>,<1-5><1-5><1-5><1-
5><1-5>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
layer assignments = Fill Layer
Note: The layer assignments are from bottom to top. The default draw order is 12345.
Example:
SEND_COMMAND Panel,"'^BDO-530,1&2,51432'"
Sets the button's variable text 530 ON/OFF state draw order (from bottom to top) to
Border, Fill, Text, Icon, and Image.
Example 2:
SEND_COMMAND Panel,"'^BDO-1,0,12345'"
Sets all states of a button back to its default drawing order.
^BFB
ONLY works on General-type buttons.
Set the feedback
Syntax:
type of the button.
"'^BFB-<vt addr range>,<feedback type>'"
Variable:
variable text address range = 1 - 4000.
feedback type = (None, Channel, Invert, On (Always on), Momentary, and Blink).
Example:
SEND_COMMAND Panel,"'^BFB-500,Momentary'"
Sets the Feedback type of the button to 'Momentary'.
^BIM
Syntax:
Set the input
"'^BIM-<vt addr range>,<input mask>'"
mask for the
Variable:
specified address.
variable text address range = 1 - 4000.
input mask = Refer to the Text Area Input Masking section on page 188 for character
types.
Example:
SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"
Sets the input mask to ten 'A' characters, that are required, to either a letter or digit
(entry is required).
= 1
Image Layer = 2
Icon Layer
= 3
Text Layer
= 4
Border Layer = 5