Syntax:
^GLH
Change the
"'^GLH-<vt addr range>,<bargraph hi>'"
bargraph upper
Variable:
limit.
variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 ( bargraph upper limit range ).
Example:
SEND_COMMAND Panel,"'^GLH-500,1000'"
Changes the bargraph upper limit to 1000.
^GLL
Syntax:
Change the
"'^GLL-<vt addr range>,<bargraph low>'"
bargraph lower
Variable:
limit.
variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 ( bargraph lower limit range ).
Example:
SEND_COMMAND Panel,"'^GLL-500,150'"
Changes the bargraph lower limit to 150.
^GRD
Syntax:
Change the
"'^GRD-<vt addr range>,<bargraph ramp down time>'"
bargraph
Variable:
ramp-down time
variable text address range = 1 - 4000.
in 1/10th of a
bargraph ramp down time = In 1/10th of a second intervals.
second.
Example:
SEND_COMMAND Panel,"'^GRD-500,200'"
Changes the bargraph ramp down time to 20 seconds.
^GRU
Syntax:
Change the
"'^GRU-<vt addr range>,<bargraph ramp up time>'"
bargraph
Variable:
ramp-up time in
variable text address range = 1 - 4000.
1/10th of a
bargraph ramp up time = In 1/10th of a second intervals.
second.
Example:
SEND_COMMAND Panel,"'^GRU-500,100'"
Changes the bargraph ramp up time to 10 seconds.
^GSC
A user can also assign the color by Name and R,G,B value (RRGGBB or RRGGBBAA).
Change the
Syntax:
bargraph slider
"'^GSC-<vt addr range>,<color value>'"
color or joystick
Variable:
cursor color.
variable text address range = 1 - 4000.
color value = Refer to theRGB Values for all 88 Basic Colors table on page 133.
Example:
SEND_COMMAND Panel,"'^GSC-500,12'"
Changes the bargraph or joystick slider color to Yellow.