CBX CONNECTION BOX PINOUT

The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the Matrix 320 reader is connected by means of the CBX100/500:
Group
Input
Power
Inputs
Outputs
Auxiliary
Interface
ID-NET
Main
Interface
* Do not leave floating, see
Label
Description
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
+V
Power Source - External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference - External Trigger
+V
Power Source - Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference - Inputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
O3A
Output 3 - non opto-isolated (only available through CBX500)
TX
Transmit Data
RX
Receive Data
SGND
Auxiliary Interface Signal Ground
REF
Network Reference
ID+
ID-NET network data +
ID-
ID-NET network data -
Shield
Network Cable Shield
RS232
TX
TX+
RX
*RX+
-
TX-
-
*RX-
SGND
SGND
RS422 Full Duplex Interface" on page 65
"