ELECTRICAL CONNECTIONS

3.2 CBX CONNECTION BOX PINOUT

The STS400™s all connect to the CBX500 ATS-001 as shown in the previous diagram. The
table below gives the pinout of the CBX terminal block connectors.
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference – Inputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
REF
Network Reference
ID+
ID-NET™ network +
ID-
ID-NET™ network -
Shield
Network Cable Shield
* Do not leave floating, see par. 3.5.2 for connection details.
NOTE: To avoid electromagnetic interference when the reader is connected
to a CBX connection box, verify the jumper positions in the CBX as indicated
in its Installation Manual.
CBX500 ATS Terminal Block Connectors
Input Power
Inputs
Outputs
Auxiliary Interface
ID-NET™
Main Interface
RS232
TX
RX
RTS
CTS
SGND
RS485
Full-Duplex
TX+
*RX+
TX-
*RX-
SGND
3
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents