RAPID CONFIGURATION

Learn

7. Enter the Learn function by pressing and holding the X-PRESS push button until
8. Release the button to enter the Learn function. The Learn LED will blink until the
NOTE
NOTE
NOTE
NOTE
1. The Learn procedure will not recognize the following symbologies: Postal Codes, Pharmacode,
6
MATRIX 320
Figure 9 - X-PRESS Interface: Learn Function
the Learn LED is on.
procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters for
a single code are successfully saved in the reader memory, the Green Spot is acti-
vated, the Learn LED will stop blinking and Matrix 320 emits 3 high pitched beeps
If the autolearning cannot be reached after a timeout of about 3 (three) minutes
Matrix 320 will exit without saving the parameters to memory, the Learn LED will
stop blinking and in this case Matrix 320 emits a long low pitched beep.
The Grade A Barcode Test Chart cannot be used to set the Code 128 sym-
bology (even though the reader successfully reads the code). Use the
application specific code if you need to set this symbology.
When using X-PRESS or the BM150 menu to perform Auto-Learn, only a
single code can be configured (successive Learns will substitute the
current code). To configure multiple codes, use the DL.CODE Auto-Learn
procedure.
You can always exit from any X-PRESS function at any time by pressing
the X-PRESS push button once. After a short delay the procedure is can-
celed.
If you have used this procedure to configure Matrix 320, go to step 9.
MSI, Standard 2 of 5, Matrix 2 of 5.