CBX ELECTRICAL CONNECTIONS

Output 1 and 2 Connections Using External Power

Output 3 is not opto-isolated but can be assigned to the same events. By default it is
not assigned to any event. The CBX500 must be used to connect this output.
NOTE
80
MATRIX 320
Figure 64 - PNP/Open Emitter Output Using External Power
Figure 65 - NPN/Open Collector Output Using External Power
For Output 3, set the Line Type configuration parameter according to the
hardware connection to the CBX: NPN, PNP or Push-Pull.