Bosch Rexroth ID 200/C‑PDP Manual page 52

Id 200 profibus
Table of Contents

Advertisement

52/84
Communication with ID 200/C-PDP
Bosch Rexroth AG, MIT: ID 200, 3 842 540 399/2016-11
single write words (SW)
The command SW (single write words) only works with the mobile data carrier
MDT-H. Not with the fixed code data carrier MDT-L!
Command:
Byte
Table of contents
Byte 0
Command code (40h)
Byte 1
Number of words/RFID channel/
toggle bit
Byte 2
Word address
Byte 3
Word address
Byte 4
Data 00h...FFh
...
Data 00h...FFh
1)
Byte N
Data 00h...FFh
1) N = 4 x <WordNum> + 3
Reply:
Byte
Table of contents
Byte 0
Command code (40h)
Byte 1
Number of words/RFID channel/
toggle bit
Byte 2
Status
Byte 3
Reply counter
Byte 4
unused
Byte 5
unused
Byte 6
unused
Byte 7
unused
The antenna attempts once to write <WordNum> 32 bit words from address
<WordAddr>.
In the reply to write, <WordNum> returns the number of words to be written if
<Status> is still 0xFF (command in progress).
Once the command has been processed, <WordNum> always returns 0.
Bit no.
7
6
5
4
0
1
0
0
<WordNum>
<WordAddr> (High Byte)
<WordAddr> (Low Byte)
<Data>
<Data>
<Data>
Bit no.
7
6
5
4
0
1
0
0
<WordNum>
<Status>
<ReplyCounter>
3
2
1
0
0
0
0
0
<RFIDChannel>
<T>
3
2
1
0
0
0
0
0
<RFIDChannel>
<T>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents