Webserver
1
2
3
Menu item
RS485
Modem
© 2017 KOSTAL Solar Electric GmbH
4
5
5
6
Function
Bus termination: The bus termina-
tion must be activated on devices
which are at the end of the RS485
bus.
Bus bias voltage: At least one
device in an RS485 bus system must
supply the bus voltage. Activation
means that the inverter supplies the
bus bias voltage.
Protocol: Selection of protocol used
on the bus.
KOSTAL: Is used to make more PIKO
inverters or an external data logger/
energy manager accessible via the
interface.
Modbus: Is used to connect e.g.
external data loggers/energy manag-
ers to the RS485
Baud rate: Selection of the baud
rate, which is to be used for the bus
system.
Inverter address: Shows the invert-
er's set RS485 address.
This function is not supported by this
device.
7
8
9
10
A precise description of the protocol
used (e.g. TCP, RS485, KOSTAL,
Modbus-RTU), can be requested from
the Service team.
11
INFO
90