Installation
1
2
3
3
Connecting mains cable
De-energise the inverter.
1.
Ch. 4.3
Switch off DC switch on the inverter.
2.
Fig. 11
Secure it against reactivation.
3.
Correctly lay the mains cable from the power distrib-
4.
utor to the inverter.
PE
Fig. 21: Connect mains cable to the inverter
AC terminal
1
Mains cable
2
Sealing ring
3
Union nut
4
Insert mains cable into the inverter and seal with
5.
sealing ring and union nut. Tighten union nut to the
prescribed torque. Torques: 13 Nm (M40).
If screw connections are not being used, leave the
6.
blind plug in the screw connections.
© 2017 KOSTAL Solar Electric GmbH
4
5
6
7
18 mm
max. 28 mm
PE
8
9
10
11
IMPORTANT
INFORMATION
See the "Technical Data" chapter
for the dimensioning of the re-
quired AC line circuit breaker and
the cable cross-section and cable
type to be used.
If using an AC cable with an outer
diameter of 15-23 mm, the reducing
ring provided should be used.
Both single-wire (type NYY-J) and
multi-wire (type NYM-J) cables
without core end sleeves can be
used with the AC terminal.
When using cables with fine wires
(type H05../H07RN-F), core end
sleeves should be used. Ensure
that there is a contact surface of
18 mm.
IMPORTANT
INFORMATION
Existing cables and their routing
within the inverter must not be
changed. This can otherwise result
in malfunctions in the inverter.
Ch. 9.1