The data logger
A data logger is integrated in the PIKO inverter. The data
logger is a data storage system for the yield and
performance data of the inverter and the storage system.
Yield data (saving interval) can be saved every 5, 15 or
60 minutes. The data logger is set in the factory to a
saving interval of 15 minutes. The saving interval can be
changed at the "Settings" Webserver page.
Saving interval
5 minutes
15 minutes
60 minutes
Tab. 3: Saving intervals of data logger
© 2017 KOSTAL Solar Electric GmbH
4
5
6
7
Saving time
Max. 130 days
Max. 400 days
Max. 1500 days
8
9
10
11
INFO
Pay attention to the memory stor-
age time when selecting the saving
interval!
When the internal memory is full, the
oldest data will be overwritten. For
long-term backup, the data must
be backed up with a PC or sent to a
solar portal.