  • Page 1 Short Manual PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management...
  • Page 2: Eu Declaration Of Conformity

    Stoffe in Elektro- und Elektronikgeräten Germany hereby declares that the inverter PIKO 6.0 BA / 8.0 BA / 10 BA to which this declara tion refers, conforms to the following guidelines and standards. KOSTAL Solar Electric GmbH – 2015-06-30...
  • Page 3: Proper Use

    Proper use The PIKO BA inverter converts DC current into AC current. Exclusion of liability The current can be used for the following: Any use that differs from or goes beyond the stated intended purpose is con- sidered inappropriate. The manufacturer accepts no liability for any damage for consumption resulting from this.
  • Page 4: Type Plate

    MPP control range Maximum DC input voltage Hanferstraße 6 – D-79108 Freiburg Maximum DC input current +49 (0) 761-47744-100 Maximum DC short circuit current www.kostal-solar-electric.com XXXXXXX Number of feed-in phases, Output voltage (nominal), frequency, Item no.: XXXXXXXX Maximum AC output current DCinput: = XXX...XXX V...
  • Page 5 Selecting the installation side NOTE Observe the following instructions, or else warranty claims will be restricted. Select stable installation location. Protect from rain and water. No plasterboard or wooden walls. Prevent access by children. Protect from direct sunlight. Required cooling space is 200 mm vertical and Select non-flammable installation location.
  • Page 6: Installation

    To lift the inverter Installation Cooling space Mounting spaces Lift here! max.10° Lift here! PIKO BA-Inverter...
  • Page 7 Connecting AC and DC side LEBENSGEFAHR DURCH STROMSCHLAG! ОПАСНОСТ ЗА ЖИВОТА ПОРАДИ ТОКОВ УДАР. Wechselrichter spannungsfrei schalten. Изключвайте инвертора от напрежението. RISK OF DEATH DUE TO ELECTRICAL SHOCK! LIVSFARA PÅ GRUND AV ELEKTRISK STÖT! De-energise the inverter. Koppla växelriktaren spänningsfri. DANGER DE MORT PAR ÉLECTROCUTION ! ZAGROŻENIE ŻYCIA PRZEZ PORAŻENIE PRĄDEM! Mettre l’onduleur hors tension.
  • Page 8 Connecting AC, DC and battery side Option: Connecting Backup Unit 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 L1.k L1.l L2.k L 2.l L3.k L3.l Connecting control line Backup Unit Connecting battery Connecting sensor Connecting AC Connecting AC Connecting Backup Unit...
  • Page 9 Country-specific installation Option: Connecting DC1 & DC2 in parallel Battery Connecting main cable with sealing cap NOTE 3 Nm When using the parallel connection this feature must be acti- vated under the menue Settings >> Hardware settings >> String connection >> Parallel connection. Second ground connection...
  • Page 10: Commissioning The Inverter

    Data transfer Communicationboard II Commissioning the inverter DSL or LAN and CAN bus 5 Nm DSL / LAN CAN bus...
  • Page 11: Installation Wizard

    Installation Wizard* Language Select language German Enter Enter Date / time Select > Enter Language Select string connection German Enter Enter Select modus of the current sensor Enter Country setting Select country Do you really want to apply Enter this country? Confirm Country settings with YES Enter...
  • Page 12: Menu Overview

    Menu overview* Menu DC and AC DC menu DC input 1 (U,I,P) DC menu Settings menu AC menu DC input 2 (U,I,P) AC menu Battery menu Own consumption menu Phase 1 (U,I,P) Phase 2 (U,I,P) Phase 3 (U,I,P) Total yield Yield (MWh) Operation time (h) Grid parameters...
  • Page 13: Settings Menu

    Settings menu Basic settings Language Select language Inverter name Entering the name Date / time Set date / Set time of day Hardware settings String connection Paralell connection Currentsensor Position Modus Battery charge time Start time / End time Battery settings Communication Network settings 1 Auto IP...
  • Page 14 Menu Battery* Menu Consumption* Daily own consumption Own consumption (Wh) Battery status 1 Charging status (%) Own consumptions rate (%) Voltage (V) Autonomy degree (%) Charging (A) (Charge/Discharge) Own consumption (Wh) Total own consumption Battery status 2 Temperature (C°) Own consumptions rate (%) Charge cycles Autonomy degree (%) Current build.
  • Page 15: Technical Data

    Technical data Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA Input side (DC) Output side (AC) Inverter type PIKO Rated output, cos j = 1 (P ac,r Max. output apparent power, cos φ, adj Max.
  • Page 16 Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA System data System data Topology: without galvanic separation - Electronic disconnection device integrated transformerless Height 450 (17.72) Internal protection according to IEC 60529 IP 55 (inch) Protection class according to IEC 62103...
  • Page 17: Service Hotline

    Service Hotline Germany +49 761 47 74 42 22 and other countries Language: German, English 12 / 2015 edition, subject to technical changes and printing errors.