[ : No voltage compensation/output voltage limited]
Input voltage
0
Output frequency
* The above applies when V/F control mode selection
parameter is set to "0" or "1".
>1 the output voltage can be prevented
Rated voltage
from exceeding the input voltage.
[ : No voltage compensation/no output voltage limit]
Input voltage
0
Output
frequency
* The above applies when V/F control mode selection
parameter is set to "" or "".
>1 the output voltage can be prevented
Rated voltage
from exceeding the input voltage.
Note: Rated voltage is fixed at 400 V.
6.13.7 Reverse-run prohibition
: Reverse-run prohibition
Function
This function prevents the motor from running in the forward or reverse direction when it receives the
wrong operation signal.
[Parameter setting]
Title
Input voltage
High
Low
Input voltage
High
Low
Function
Reverse-run prohibition
F-35
[ : Voltage compensation/output voltage limited]
0
Output frequency
[ : Voltage compensation/no output voltage control]
0
Output
frequency
* Note that even if the input voltage is set less than
, for a base frequency of or higher output
frequency, then an output voltage over
occurs.
Adjustment range
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
E6582233
Input voltage
High
Low
Input voltage
High
Low
6
Default setting
0