Toshiba TOSVERT VF-nC3E Instruction Manual page 222

Industrial inverter (for 3-phase induction motors)
Table of Contents

Advertisement

 Communication parameters
Communicati
Title
on No.
F800
0800
Baud rate

F801
0801
Parity

F802
0802
Inverter number

F803
0803
Communication

time-out time
F804
0804
Communication

time-out action
 F808
0808
Communication
time-out detection
condition
F829
0829
Selection of

communication
protocol
F870
0870
Block write data 1

F871
0871
Block write data 2

F875
0875
Block read data 1

F876
0876
Block read data 2

F877
0877
Block read data 3

F878
0878
Block read data 4

F879
0879
Block read data 5

F880
0880
Free notes

Minimum
setting unit
Function
Unit
Panel/Comm
unication
-
-
-
-
-
1/1
s
0.1/0.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1/1
J-15
Adjustment range
3: 9600bps
4: 19200bps
5: 38400bps
0: NON (No parity)
1: EVEN (Even parity)
2: ODD (Odd parity)
0-247
0.0: Disabled,
0.1-100.0
0: Alarm only
1: Trip (Coast stop)
2: Trip (Deceleration stop)
0: Valid at any time
1: Communication selection of
fmod or cmod
2: 1 + during operation
0: Toshiba inverter protocol
1: Modbus RTU protocol
0: No selection
1: Command information
2: -
3: Frequency command value
4: Output data on the terminal board
5: Analog output for communication
0: No selection
1: Status information
2: Output frequency
3: Output current
4: Output voltage
5: Alarm information
6: PID feedback value
7: Input terminal board monitor
8: Output terminal board monitor
9: VI terminal board monitor
0-65535
E6582233
Default
User
Reference
setting
setting
4
6.21
1
0
0.0
0
1
0
0
0
0
0
0
0
0
0
6.22
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents