– The left B6 bundle contains 6A, 6B, 6C, and 6D. This bundle attaches to the clip (C).
– The right B6 bundle contains 6W, 6X, 6Y, and 6Z. This bundle attaches to the clip (E).
Four system node configuration: The four system node configuration has twelve cable bundles.
Figure 276. Bundling and connecting SMP cables for four system nodes
• Two bundles named B1 with the "1" cables.
– The left B1 bundle contains 1A, 1B, 1C, and 1D. This bundle attaches to the clips (A).
– The right B1 bundle contains 1W, 1X, 1Y, and 1Z. This bundle attaches to the clips (L).
• Two bundles named B2 with the "2" cables.
– The left B2 bundle contains 2A, 2B, 2C, and 2D. This bundle attaches to the clips (B).
– The right B2 bundle contains 2W, 2X, 2Y, and 2Z. This bundle attaches to the clips (K).
• Two bundles named B3 with the "3" cables.
– The left B3 bundle contains 3A, 3B, 3C, and 3D. This bundle attaches to the clips (C).
– The right B3 bundle contains 3W, 3X, 3Y, and 3Z. This bundle attaches to the clips (J).
• Two bundles named B4 with the "4" cables.
– The left B4 bundle contains 4A, 4B, 4C, and 4D. This bundle attaches to the clip (D).
– The right B4 bundle contains 4W, 4X, 4Y, and 4Z. This bundle attaches to the clip (G).
• Two bundles named B5 with the "5" cables.
– The left B5 bundle contains 5A, 5B, 5C, and 5D. This bundle attaches to the clip (E).
– The right B5 bundle contains 5W, 5X, 5Y, and 5Z. This bundle attaches to the clip (H).
• Two bundles named B6 with the "6"cables.
– The left B6 bundle contains 6A, 6B, 6C, and 6D. This bundle attaches to the clip (F).
– The right B6 bundle contains 6W, 6X, 6Y, and 6Z. This bundle attaches to the clip (I).
5. Review the following information to identify the locations where each UPIC cable connects to the
system node that you are servicing and to the system control unit. Then, refer to your labels and the
following steps to reconnect the UPIC cables that you removed from the system node you are
servicing.
Note: You will reconnect the UPIC cables to the system control unit in a later step.