Safety
1.3
Notes on CE Marking
The following apply to the surfaceCONTROL 3D 35xx:
- EU Directive 2014/30/EU
- EU Directive 2011/65/EU
Products which carry the CE mark satisfy the requirements of the EU directives cited and the relevant applicable
harmonized European standards (EN). The measuring system is designed for use in industrial environments.
The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according
to the EU Directives.
1.4
Intended Use
- The surfaceCONTROL 3D 35xx measuring system is designed for use in industrial applications.
Non-contact optical measurement of diffuse reflective surfaces
Quality monitoring as well as form/position and surface inspection
- The system must only be operated within the limits specified in the technical data, see Chap. 3.2.
- The sensor must be used in such a way that no persons are endangered or machines and other material goods are
damaged in the event of malfunction or total failure of the sensor.
- Take additional precautions for safety and damage prevention in case of safety-related applications.
1.5
Proper Environment
- Protection class
Sensor:
Optical paths during operation are excluded from the protection class.
Contamination of the paths causes impairment or failure of the function.
The IP67 protection class is a specification that is limited to protection from dust and water. Oil, steam and emulsion
effects are not included in this protection class and must be evaluated separately.
- Temperature range
Operation:
Storage:
- Humidity:
- Ambient pressure:
1) Max. permissible operating temperature depends on installation scenario, thermal connection and operating mode.
If necessary, external heat dissipation must be used to ensure that the sensor's internal temperature of 60 °C is not ex-
ceeded.
surfaceCONTROL 3D 35xx
IP67 (only applies in the case of connected output connectors and/or installed protective caps)
1
0 ... +45 °C
(+32 ... +113 °F) (with appropriate heat dissipation)
-20 ... +70 °C (-4 ... +158 °F)
20 ... 80 % (non condensing)
Atmospheric pressure
Seite 6
Need help?
Do you have a question about the surfaceCONTROL 3D 35 Series and is the answer not in the manual?