Appendix | Genicam surfaceCONTROL Parameters
A 3
Genicam surfaceCONTROL Parameters
Details about setting the parameters are available in the software description, see 3D View operating instructions.
Parameter Description
Observe the notes below if you operate the sensor with a third party library for Genicam/GigE Vision:
- The library must support GigE Vision 2.1. In particular, MultiPart mode must be supported.
- Three sources are available to set the parameters of the sensor, see the SourceSelector description below. Howev-
er, data are always transmitted using StreamChannel 0. Before starting data transmission with the Acquisition-
Start command, the entry Source0 must be selected as SourceSelector.
- The network card used should be configured as follows:
ƒ Jumbo frames: enable/use largest possible value
ƒ Interrupt throttling: enable
ƒ Interrupt throttling rate: adaptive
ƒ Receive buffer: use largest possible value
- The Coord3D_C32f pixel format is used for 3D measurements. If this pixel format is not supported by the library
used, the Mono16 pixel format can be used as an alternative. In that case, however, the resolution or measuring range
is limited.
- The operating mode and sensor data transmitted are controlled using the parameter ComponentEnable and the
associated selectors SourceSelector, RegionSelector and ComponentSelector, as well as via TriggerMode
and TriggerSoftware. The following modes are possible, among others:
ƒ Setup operation (continuous transmission of raw images):
ƒ TriggerMode = Off
ƒ ComponentEnable [Source1][Region0][Intensity] = 1
ƒ ComponentEnable [Source2][Region0][Intensity] = 1
ƒ Set all other selector combinations for ComponentEnable to 0
ƒ SourceSelector = Source0
ƒ Command AcquisitionStart
- Measuring operation 3D (triggered continuous 3D measurement):
ƒ TriggerMode = On
ƒ TriggerSource = Software
ƒ ComponentEnable [Source0][Scan3dExtraction0][Range] = 1
ƒ If you want a mask image for invalid points:
ComponentEnable [Source0][Scan3dExtraction0] [Confidence] = 1
ƒ Set all other selector combinations for ComponentEnable to 0
ƒ SourceSelector = Source0
ƒ Command AcquisitionStart
ƒ Trigger any number of measurements by using command TriggerSoftware