Troubles
Bluetooth 
You cannot use Bluetooth communication and Pairing in 
communication fails.
the case of these below:
・   B luetooth setting is off on the smartphone.
Pairing fails.
・ Application shut down.
・ Battery charge is low.
・ In-flight mode is on.
・   P aring has not been done correctly. (Please clear pairing 
of both smartphone and watch if you did the pairing with 
another smartphone.)
・ Communication may fail depending on the environment.
Please re-pairing after clearing pairing of both smartphone 
and watch if you did the pairing with another smartphone.
6
158
How to reset the system
In the case that the watch moves abnormally, reset the system. Then the watch will re-
sume its normal operation.
①   P ress  and  hold  Button 
,  Ⓓ  and  Ⓕ  simultaneously.  When  the  display  becomes 
blank, release all the buttons.
Button Ⓒ
Button Ⓑ
Button Ⓐ
② The system is reset.
6
   W hen the watch is recovered from the blank display, it shows the time in the time/cal-
endar mode. The time and calendar start moving from midnight on January 1, 2016.
   T o show the correct time on your watch, make sure to set the time after the system is 
reset.
160
Solutions
Button Ⓓ
Button Ⓔ
Button Ⓕ
Troubles
Automatic time 
Automatic time synchronization is not performed in case of 
the following:
synchronization is not 
・   A utomatic time synchronization mode is off on the 
performed.
application.
・ Paring has not been done correctly.
・ Watch and Smartphone are not close.
・   A pplication is open when the automatic time 
synchronization is performed.
・ Sleep mode is on at the watch.
Please make sure to synchronize after you turn on the 
Automatic time synchronization; otherwise, the Automatic 
time synchronization is not performed.
T i m e   s e t t i n g   i s 
The setting such as time or alarm is overwritten after the 
changed
setting synchronization  is performed. 
The  time  on  the  watch 
Please confi  rm that the location information setting of your 
is  different  from  the 
smartphone is  accessible. Please confi  rm the  last setting 
smartphone time.
synchronization time.

Specifications

1. Frequency of crystal oscillator ···· 32,768 Hz (Hz = Hertz ... Cycles per second)
2. Loss/gain (monthly rate)  · ·············· Less than 20 seconds at normal temperature range (between 5℃ and 35℃)
3. Operational temperature range  ··· between −10℃ and +60℃ (Temperature range for display function between 0℃ and+50℃)
4. Display medium  · ································ Nematic Liquid Crystal, FEM (Field Eff  ect Mode)
5. Power source ····································· Secondary battery, 1 piece
6. Duration of operation ······················   A pproximately 5 months without being recharged after fully charged, under the 
conditions that the illuminating light is turned on once within 2 seconds per day, 
the alarm is sound once for 10 seconds per day, altitude and temperature is 
measured for 10 hours per month, the compass is used for 10 times per week, 
and the power save mode is activated for 6 hours per day.
7. Illuminating light································ EL (Electroluminescent panel)
8. IC (Integrated Circuit) ····················· Oscillator, frequency divider and driving circuit, C-MOS-IC, 6 pieces
9. Pressure sensor································ Altimeter:Display unit 1m/5ft
 
Measurement range between −699 and 9164m/between −2290ft and 30065 ft.
 
Accuracy Altitude lower than 6000m : ±(diff  erence in altitude×3%+30m)
 
Altitude higher than 6000m : ±(diff  erence in altitude×3%+45m)
 
Temperature range to ensure accuracy between −5℃ and 40℃
 
Barometer:Display unit 11hPa/0.01hHg
 
Display range between 300 and −1100 hPa/between 8.85 and 32.48 InHG
 
Accuracy ±3hPa
 
Temperature range to ensure accuracy Between −5℃ and 40℃
10. Magnetic sensor  · ··························· Directional angle resolution 1°
 
Measurement range between 0 and 359°
 
Accuracy ±10°
 
Temperature range to ensure accuracy  Between 10 ℃ and 40 ℃
11. Temperature sensor ····················· Display unit 1ºC/1ºF
 
Measurement range between −10℃〜60℃/−14°F〜140°F
 
Accuracy ±3℃
 
Temperature range to ensure accuracy  Between −5℃〜 and 50℃
※The specifi  cations above are subject to change without prior notice, for product improvements.