Periodic Check
1.5.3
Ozone Filter
[1]
1.5.4
Toner Cartridge (C/M/Y/Bk)
[2]
4138fs2512c0
[1]
4138fs2501c0
4138fs2502c0
2-10
Main Unit Field Service
A. Replacement Procedure
1. Hold onto the handle of the Ozone
Filter [1] and slide it out of the
machine.
2. Install a new Ozone Filter in the
machine.
3. Replace the Transfer Roller.
☞ 2-15
A. Removal Procedure
1. Open the Front Door.
2. Press the "Push" mark [1] on the
Toner Cartridge and slide out the
Toner Cartridge.
3. Holding the Toner Cartridge [2] as
shown in the illustration on the left,
slide it out of the machine.