Intended Use; Predictable Misuse; System Description Maico Smart Network With Radio Electronics - Maico ECA 100 ipro RC Mounting And Operating Instructions

Small room fans
Hide thumbs Also See for ECA 100 ipro RC:
Table of Contents

Advertisement

Available languages

Available languages

3.2 Intended use

● Small room fan for the ventilation of
bathrooms, WCs. storage rooms, offices,
change cubicles and similar spaces.
● Up to 3 fans can be networked to one
another.
● The unit is only intended for domestic use
and similar purposes.
● Operation is only permitted with:
● a fixed installation within buildings.
● a surface installation on walls, ceilings
or ducts.
● an air supply via shaft or duct.
● a permanent electrical connection,
(recessed-mounted).
● sufficient space from the wall or ceiling.
● a unit that is completely installed.
● outside air openings as laid out in the
planning documentation.

3.3 Predictable misuse

Maico is not liable for damages caused by
use contrary to the intended use. Under no
circumstances should the unit be used:
● in combination with range hoods or
laboratory extractors.
● in single air extraction systems according
to DIN 18017-3.
● close to flammable materials, liquids or
gases,
● for the conveying of chemicals, aggressive
gases or vapours.
● in explosive atmospheres.
● outdoors,
● if there is no protection against accidental
contact with the impeller on the discharge
side in accordance with EN ISO 13857.
Do not install switches and control
components near showers - there is no
splash water protection.
3.4 System description Maico smart
Network with radio electronics  fold-out
page
Maico Smart with ECA100 ipro units
● Receivers are ECA 100 ipro fans from the
RC and RCH unit models.
● Transmitters are system components
such as RLS RC room air control, DS RC
radio switches, radio window contacts and
further ECA 100 ipro fans from the RC and
RCH unit models.
● All the ECA 100 ipro RC/RCH models in the
network can be combined with each other.
● RCH units also have a humidity control
(fully automatic humidity operation).
● The system can be operated with a radio
switch and /or RLS RC:
● Per radio switch, 2 performance levels
can be selected, or the system can be
switched off.
● With the RLS RC3 room air control,
3 system levels can be switched on
manually ( see table in Chapter 10).
● This function is deactivated ex works in
order to guarantee continuous ventilation. If
need be, this function can also be activated
( see RLS RC) mounting instructions).
● The fan can also be switched on/off with
radio window contacts (window open/closed).
● During commissioning, the transmitters
must be taught-in on the receivers (must
be paired with each other).
ECA 100 ipro RC
● Two-level, 78 m³/h or 92 m³/h.
● Performance levels can be set manually
with radio switch and/or automatically with
RLS RC radio controller.
ECA 100 ipro RCH
Model similar to the ECA 100 ipro RC with
additional fully automatic humidity control.
Normally, the fan runs in standard operation
at a performance level that is manually set or
predefined through an RLS RC.
When starting up the RCH fan, this fan is set
in line with the current relative room humidity.
EN
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eca 100 ipro rch

Table of Contents