1.
Only lay single cable cores in the unit. To
do this, remove power cable sheathing
over a length of 90 mm. Strip single cable
cores to 9 to 10 mm.
2.
Insert housing [1] into wall breakthrough/
wall sleeve and secure with two screws.
Do not insert the housing such that it is
twisted or crushed. Make sure you use
mounting material which is sized for the
purpose.
3.
Electrically connect power cable to spring
clip [11] according to connection wiring
diagram [12]  wiring diagrams in Chap. 16.
4.
Check position of cable grommet. It must
be well sealed.
5.
Fit electronics cover.
Danger of short-circuits and
NOTICE
damage to the unit. Humidity
will penetrate if electronics
cover is not positioned correctly.
Press electronics cover firmly
onto housing such that it is
sealed and flush all the way
around. Do not press the set up
button [10].
6.
Locate the 3 locking tabs on the electronic
cover over the housing cut-outs I, II and III
and press the cover in, until the tabs engage.
In addition, press the electronics cover
firmly on to the housing at the points
indicated by the word "PRESS".
7.
With RCH unit models, plug the supplied
sensor [9] correctly (arrow X) into the
connector sockets.
8.
Fit cover [6].
Fit designer cover [7] (  fold-out page,
9.
Fig. B).
10.
Install all other system components
according to their mounting instructions.

8.3 Commissioning

Operation with a single fan (individual
operation)
1.
Switch the mains fuse on.
2.
First set up the RLS RC room air control
and then the radio switch and/or radio
window contacts at the fan, as described
in Chapter 9.
3.
Set up the remaining system components.
4.
Carry out a function test with all system
components.
Operation in master/slave network
1.
Switch the mains fuse on.
2.
Set up the pre-configured RLS RC room
air control at the master fan.
3.
Set up the radio switch, radio window
contacts and further slave fans at the
master fan, as described in Chapter 9.
4.
Set up further radio switches and/or radio
window contacts at the slave fans (max.
2 fans).
5.
Carefully press the cover [6] (with designer
cover [7]) onto the housing, until it locks
into the safety catches.
6.
Carry out a function test with all system
components.
EN
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eca 100 ipro rch