Technical Data; Scope Of Delivery; Intended Use - Maico AS 20 Original Installation Instructions

Shutter
Hide thumbs Also See for AS 20:
Table of Contents

Advertisement

Available languages

Available languages

Installation instructions for shutters
Installation instructions for shut-
ters
NOTE
Please read the instructions carefully before in-
stalling and using for the first time.
Follow the instructions.
Pass these instructions on to the owner for safe-
keeping.
Go directly to the product with a smartphone. On-
line at www.maico-ventilatoren.com or QR code
for direct access:
1 Safety
WARNING Risk of injury in entrance
areas when ice forms due to falling icicles.
Never install the shutter above entrance areas
that are not covered.
WARNING Risk of injury when working at
heights.
Use appropriate climbing aids (ladders).
Stability should be ensured, if necessary have
the ladders steadied by a 2nd person.
Ensure that you are standing securely and can-
not lose your balance and that there is no one
under the unit.
CAUTION when handling packaging ma-
terials.
Observe applicable safety and accident preven-
tion regulations.
Store packaging material out of the reach of chil-
dren (risk of suffocation due to swallowing).

2 Scope of delivery

Shutter, protective grille, these installation and
operating instructions.

3 Intended use

Self-opening/closing shutters for extracting air
from rooms – these also serve as weather protec-
tion and cold air barriers. With galvanised protect-
ive grille as protection against accidental contact
according to DIN EN ISO 13857.
4
From nominal size 35 with central support to in-
crease shutter stability.
Recommended accessories for ZVR connection
frame (fixing the shutter to the fan instead of to
the wall).
Operation is only permitted with:
• a permanent installation, mounted on a wall
with sufficient load-bearing capacity.
• installation using suitable mounting material.
• a vertical/horizontal installation position.
• installation using protective grille with free air in-
let or outlet for a fan.
The shutters are only intended for domestic use
and similar purposes. No other or additional use
is intended.

4 Technical data

For more technical data → Internet, maico-ventil-
atoren.com.
Material
Weight depending on
type
Nominal sizes [A], dimensions [B]...[E]
Dimensions in [mm]
A
B
AS 20
200
39
AS 25
255
40
AS 30
307
40
AS 35
360
40
AS 40
412
40
AS 45
465
41
AS 50
517
41
AS 60
622
42
Plastic, weather-resist-
ant and UV-resistant
0.4 - 2.6 kg
C
D
E
260
197
182
314
250
234
366
300
286
420
355
338
472
405
390
526
460
442
578
510
494
684
615
598