Operating Procedure/Photos
Remove capillary
Unsolder the soldering joint between capillary and valve and
exit tube of condenser and then remove the capillary. Please
do not let the welding slag block the capillary when replacing
the capillary. As shown in fig 7-44
Remove valve
Twist off the 2 bolts used for fixing the gas valve, unsolder the
soldering joint between gas valve and air-return pipe and
then remove the gas valve.
(Note: when unsoldering the soldering joint, wrap the gas
valve with wet cloth completely to avoid the damage of valve
due to high temperature)
Twist off the 2 bolts used for fixing the liquid valve, unsolder
the soldering joint between liquid valve and Y-type tube and
then remove the liquid valve. As shown in fig 7-45
Remove compressor
Unsolder the pipeline connected with the compressor and
remove the 3 foot nuts on compressor, and then remove the
compressor. As shown in fig 7-46
capillary
liquid valve screw gas valve
compressor
foot nut