(4) Fan Mode
In fan mode, the indoor fan operates at setting fan speed.
(5) Fan Mode
In AUTO mode, the unit will automatically select its operation mode (cooling, heating or fan) with the change of ambient
temperature.
3 other control
(1) Up&down swing control
After energization, up & down swing motor will firstly let the horizontal louver anticlockwise rotate to position 0 to close air
outlet.
If swing function has not been set after startup of the unit, up & down horizontal louver will clockwise turn to position D in
HEAT mode, or clockwise turn to level position L1 in other modes. Indoor fan and compressor can be energized only after
the horizontal louver is opened at L1 position.
If setting swing function while starting up the unit, the horizontal louver will swing between L and D. There are 7 kinds of
swing status of horizontal louver: Positions L, A, B, C and D, swing between Land D and stop at any position between L and
D (angles between L and D are equiangular). Upon turning off the unit, the horizontal louver will close at position 0. Swing
function is available only when swing function set and indoor fan is operating. In heating and auto heating mode, when
Tamb.>Tpreset+2℃, the up&down horizont al louver will turn to the breeze position W.
(2) Buzzer
Upon energization or availably operating the unit or remote controller, the buzzer will give out a beep.
(3) Button
After energization, press this button once and then the unit will operate at auto mode; press it again to turn off the unit.
(4) Display of displayer
(1) Display of operation icon and mode icon
A. After energization, all the display icons will be displayed and then only the power LED is bright.
B. When turn on the unit by the remote controller, the operation LED will be bright. Meanwhile, the current operation mode
LED will be bright;
In cooling mode and auto cooling mode, the operation LED and the cooling LED are bright;
In heating mode and auto heating mode the operation LED and the heating LED are bright;
C. Setting auto quiet or forced quiet, the quiet lamp is bright; if the correct humidity data does not receive for 10min
continuously,
the quiet lamp blinks (only blinks after setting auto quiet or forced quiet, and stop to blink after turn off quiet function).
D. Sleep LED will be bright when setting sleep function.
E. All the display will be OFF if turn of the light button (this is still available in off status).
F. After setting sleep function, the displayer will keep the previous display status. That's the sleep function won't affect the
on or off status of light.
(2) Dual-8 display
The nixie tube displays the current setting temperature (the setting temperature range is 16-30℃). In auto mode, it displays
25℃ in cooling and fan and 20℃ in heating. It only displays 25℃ for cooling only controller. H6 will be displayed for the
motor locked information. H1 will be displayed during defrosting period.
(5) Auto fan speed control
In this mode, the indoor fan will select the high, medium and low fan speed according to the change of ambient
temperature.
(6) X-Fan Function
① In the cooling or drying mode( X-Fan function is not available for auto, heating and fan mode), the X-Fan function can
be set. After X-Fan function is turned on, if turn off the unit by pressing ON/OFF button, indoor fan will run at low fan speed
for 10mins (within the 10mins, swing will operate at the original status, while other loads will be tuned off) and then the
complete unit will be turned off; After the X-Fan function is turned off, the complete unit will be turned off after pressing
ON/OFF button.
② When the X-Fan function is started, if press the X-Fan button, indoor fan will stop operation immediately and the guide
louver will be closed.
0
heating angle
0
cooling angle