The fan doesn't run
when setting the fan
The compressor is
running while the out-
door fan doesn't run
in cooling and heating
mode
The outdoor fan is
running, while the
compressor doesn't
run in cooling and
heating mode
Compressor is sub-
heatingand leads to the
protector is activated.
The swing louver
doesn't run
The indoor fan motor is burned out or damaged,
or there's malfunctionthe for heat protector
The built-in heat protector of the motor breaks
frequently because of subheating leaded by the
abnormal motor
Wrong wire connection
The fan capacitor is break circuit or damaged
The motor of outdoor fan is damaged
Wrong wire connection
The capacitor of outdoor fan is damaged
There's malfunctionfor for the compressor
Compressor's running capacitor is broken
The voltage is low or high
Wrong wire connection
There's malfunction for protector
The refrigerant is too much
The capillary is blocked and the suction
temp. is rising.
The compressor doesn't run smoothly or is stucked.
The air discharge valve is damaged
There's malfunction for protector
The torque of swing motor is not enough
Wrong wire connection
The controller is damaged( IC2003 is broken,
swing relay can't be suction to close)
Replace the fan motor or the defective parts
Replace the fan motor
Connect the wire correctly basing on the circuit
drawing
Replace the fan capacitor with the same mode
and specification
Replace the fan motor
Connect the wire correctly basing on the circuit
drawing
Replace the fan capacitor
Replace the compressor
Replace the capacitor
Suggesting to equip with the manostat
Connect the wire correctly basing on the circuit
drawing
Use the multimeter to check whether the contact point of
the compressor is conducted at the time of not subheating.
If it isn't conducted, please replace the protector.
Adjust the volume of the refrigerant
Replace the capillary
Replace the compressor
Replace the protector
Check the wire connection. If the wire connection
is correct, then replace those parts on the malfun-
ction position