Operating Procedure/Photos
Remove motor and motor support
Twist off the 4 tapping screws used for fixing the motor and
then remove the motor. Twist off the 2 tapping screws used
for fixing the motor support, pull it upward and then remove
the motor support. As shown in fig 7-19.
Remove capillary
Unsolder the soldering joint between capillary and other
pipelines and then remove the capillary. As shown in fig 7-20.
Remove gas valve and liquid valve
Twist off the 2 bolts used for fixing the gas valve, unsolder the
soldering joint between gas valve and air-return pipe and
then remove the gas valve.
(Note: When unsoldering the soldering joint, wrap the gas
valve with wet cloth completely to avoid the damage of valve
due to high temperature.)
Twist off the 2 bolts used for fixing the liquid valve, unsolder
the soldering joint between gas valve and Y-type tube and
then remove the liquid valve. As shown in fig 7-21.
Admiral Series
motor support
tapping screw
motor
Fig.
capillary
liquid valve
gas valve
bolt
Fig.
Fig.