Console Interface; Alarm Output Interfaces; Table 2-12 Parameters Of The Console Interface - Raisecom Gazelle S1020i-GL Series User Manual

Table of Contents

Advertisement

Raisecom
Gazelle S1020i-GL (A) User Manual
Transmission rate
Duplex mode
Specifications

2.3.3 Console interface

Table 2-12 lists parameters of the Console interface.

Table 2-12 Parameters of the Console interface

Connector type
Duplex mode
Electrical feature
Baud rate

2.3.4 Alarm output interfaces

The alarm output interface is embedded with an electromagnetic relay. When alarms are input
through the DI interface or overtemperature, abnormal interface status, or abnormal power
status occurs, the electromagnetic relay will output alarms based on the connection status of
the control terminal, notifying the on-site operation and maintenance personnel, and
meanwhile report the alarms to the Network Management System (NMS).
Alarm output interface 1
The alarm output interface on the Gazelle S1020i-2GF-4GE-PWH-GL-DC48 and Gazelle
S1020i-4GF-8GE-PWH-GL-DC48 shares the 8-pin Phoenix connector interface with the
power supply. The alarm output interface is in form of 3-pin Phoenix connector with spaces
of 5.08 mm, as shown in Figure 2-13.
Parameter
10/100/1000 Mbit/s auto-negotiation
Full/Half duplex
When the transmission rate is 10/100 Mbit/s, we recommend
using Cat 5 or better STP cable.
When the transmission rate is 1000 Mbit/s, we recommend using
Cat 6 or better STP cable.
Parameter
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Description
Description
RJ45
Duplex UART
RS-232
9600 baud
2 Hardware structure
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents