Raisecom
Gazelle S1020i-GL (A) User Manual
Table 4-1 Requirements for the operating environment
Operating temperature (altitude: 0–1800 m)
Operating humidity
Storage temperature
Operating air pressure
4.1.3 Power supply conditions
Table 4-2 lists power supply requirements for operation of the Gazelle S1020i-GL.
Table 4-2 Power supply requirements for operation
Power supply
Power consumption
RPS
4.1.4 Static electricity conditions
To prevent body static electricity from damaging the Gazelle S1020i-GL, wear the Anti-Static
Discharge (ASD) wrist strap properly any time when you contact the Gazelle S1020i-GL.
4.1.5 Grounding conditions
The Gazelle S1020i-GL must be grounded, and the ground resistance should be no smaller
than 1 Ω. Well grounding is the first guarantee for lightning protection and anti-interference.
4.1.6 Other conditions
Before installing the Gazelle S1020i-GL, check whether auxiliary parts are ready. For
example, ensure that cables and supporting devices are properly installed.
Replacing a card or altering the device may cause extra hazard. Do not do this if you are not a
professional technician.
To guarantee safety, please contact Raisecom local office or technical support hotline for any
questions.
Parameter
Parameter
For details, see section 3.1 Overall parameter.
The power supplied by the power supply should exceed the
maximum power consumption.
We recommend preparing a professional RPS in case of
abnormal power supply.
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
4 Hardware installation
Description
-40 to 75° C
5%–95% RH (non-condensing)
-45 to 85° C
86–106 kPa
Requirement
47