3 SPECIFICATIONS
Buffer memory name
Execution pattern
setting
Start mode
Time scale
Final segment
Output time of pattenend
3 - 25
The following gives the detailed explanation of control data, program pattern, and
zone PID data.
(a) Control data
Common data required for executing the program control are sets.
Sets a program to be executed selecting from the
program patterns 1 to 3
Sets a starting method of set value (SV) selecting
from zero starting/PV starting 1/ PV starting 2.
Sets the executing time scale of the segment set in
program pattern data.
(b) Program pattern data
Program pattern consists of segments, which have set value, time (execution
time), and zone PID data No.
The Q62HLC can set up to 3 patterns of 16-segment program pattern at the
maximum.
Several program patterns can be linked by pattern link (refer to the next page for
buffer memories).
Pattern link
Iteration
Wait zone
Description
Pattern 1
Pattern 2
Segment 1
Segment 2
Segment 16
MELSEC-Q
Buffer memory address (Decimal)
CH1
272
273
274
Pattern 3
Each segment
Set value (SV)
Executing time
Zone PID data No.
CH2
528
529
530