flange integrated on the body, and screwed
together using the enclosed screws. Any
sheeting used on site can be used as seal
sheeting. For installation in waterproof con-
crete (white tub), KESSEL also has mat-
ching seal sheeting available made of natu-
ral rubber NK/SBR, where the bore holes for
the screws have already been cut out (art.
no. 83023, see Fig. 7). Maximum ground-
water resistance is 2 m.
Moving the sealing level into the upper
cover section requires a modified set-up
where the KESSEL chamber system LW
400 is used (see Fig. 8).
The individual parts required are shown in
the current KESSEL sales documentation. If
it is necessary to perforate the waterproof
concrete tub to connect feed pipes, cable
conduits etc., these holes must also be set
up waterproof.