Before installing the KESSEL lifting sta-
tion qualift S all parts must be checked
for transport damage.
The pump tank must be aligned horizontal-

2.1 Installation in the ground plate

ly. If necessary, attach inlets at the side. For
this purpose, the flat surfaces of the tank, if
appropriate the adapter and upper cover
section (max. DN 50), must be pre-scored
using the
KESSEL saw cap (art. no.
50100). Then insert a suitable elastomer
seal into the bore hole and push the inlet
pipe in place (Fig. 1/2).
Fig. 1
Fig. 2
2. Installation
Caution
Do not locate inlets near the level measure-
ment, floating switch, submersible pipe in
A conduit must be provided on site for
order to avoid malfunction.
connection of the electric cables (Fig. 3).
The conduit can be mounted in the cable
duct provided in the adapter or in any other
spot by pre-scoring the tank (Fig. 1/2).
Insert the enclosed profile lip seal into
the adapter groove, grease it and fit the
upper cover section. Thanks to the design of
25
the upper cover section, the KESSEL lifting
station Aqualift S can be adapted exactly to
the prevailing installation depth. Ground slo-
pes of up to 5° can be compensated. Align-
ment of the cover e.g. to tile pattern is possi-
ble (Fig. 4).
Caution
The upper cover section must be shortened to
the necessary size to achieve minimum in-
stallation depth.
Following final alignment, near the cable duct
and where any additional inlets have been
Fig. 3
attached (Fig. 5).
Fig. 4